{"id":5381211685016,"title":"Philips - Electrocardiogram - PageWriter TC10","handle":"philips-pagewriter-tc10","description":"\u003ch4\u003eTechnical\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntended Use\u003c\/strong\u003e - Adult, pediatric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurements \u003c\/strong\u003e-\u003cstrong\u003e \u003c\/strong\u003ePhilips DXL ECG Algorithm; STEMI (ST segment elevation myocardial infarction) diagnostic aid for Culprit Artery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecorder Channels\u003c\/strong\u003e - 12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser Interface\u003c\/strong\u003e - Panel buttons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery\u003c\/strong\u003e - 2 hours continuous\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories \u0026amp; options (included)\u003c\/strong\u003e - Color touch display, welsh bulbs, 12-lead ECG algorithm, LAN option. For Wireless option: 5-Min Disclosure \u0026amp; Events, Archive \u0026amp; Inter. Query, Wireless 802.11 (a,b,g,n)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFind out more about this product\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.philips.co.uk\/healthcare\/product\/HC860392\/pagewriter-tc10-miscellaneous\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSee below for further details about the terms of this offer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eProduct Details\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch4\u003eNon Technical and Terms\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e - 36 Months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Time\u003c\/strong\u003e - Updated at time of order confirmation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping - \u003c\/strong\u003eBy Air or Sea\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService\u003c\/strong\u003e - Post-warranty service to be contracted locally by the Borrower country.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManuals\u003c\/strong\u003e - Printed user and service manuals will be provided with each piece of equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTraining\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- As part of the purchase, operator training provided at onsite for users after installing the system, if applicable. This takes place on the system purchased.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003ePricing: \u003c\/h6\u003e\n\u003cp\u003eAll prices are in USD with delivery CIP (Carriage and Insurance Paid To), place to be decided, include installation of the offered equipment and exclude VAT. Import costs, custom duties and any other additional taxes are not included.\u003c\/p\u003e\n\u003ch6\u003ePayment:\u003c\/h6\u003e\n\u003cp\u003eAdvanced payment: ten (10) percent of the Contract Price shall be paid within five (5) days of contract signing and upon submission of a claim for the amount, and thirty(30) percent of the Contract Price shall be paid within twenty (20) days of signing of the Contract and upon submission of claim and a bank demand guarantee, in the form provided in the request for invitation for direct contracting or another form acceptable to the Purchaser, for equivalent amount valid until the Goods are delivered and in the form of Advance Payment Security provided in the request for invitation for direct contracting or another form acceptable to the Purchaser.  On Shipment, sixty (60) percent of the Contract Price of the Goods shipped shall be paid, within 15 days after submission of documentation.\u003c\/p\u003e\n\u003ch6\u003eInspection\u003c\/h6\u003e\n\u003cp\u003eEquipment will be inspected by an independent agency at Philip’s warehouse (prior to shipping) to confirm quantities, shipping documentation and to ensure there is no damage to packaging. Costs related to this inspection are passed onto the Borrower Country.\u003c\/p\u003e\n\u003ch6\u003eDelivery\u003c\/h6\u003e\n\u003cp\u003ePhilips will provide delivery CIP to a designated location. Inland delivery to the hospital and local vertical transport is not included and is the Borrower country responsibility.  Under CIP the Borrower Country would be responsible for costs relating to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTerminal Charges Destination\u003c\/li\u003e\n\u003cli\u003eCustoms Clearance Import, incl. cost \u0026amp; duties\u003c\/li\u003e\n\u003cli\u003eTransport to Destination On-Carriage\u003c\/li\u003e\n\u003cli\u003eUnloading at the Borrower’s Premises\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eAbout \u0026amp; Contact\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003ePhilips Medical Systems is a global health technology company that develops and manufactures products and services for personal health, diagnosis and treatment, connected care and health informatics.\u003c\/p\u003e\n\u003ch5\u003eAbout ECG's\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003eDiagnostic electrocardiogram (ECG) units detect, record, print, and\/or display the electrical signals associated with a patient’s cardiac activity. They are used to diagnose and assist in treating some types of heart disease and arrhythmias, determine a patient’s response to drug therapy, and reveal trends or changes in heart function.\u003c\/p\u003e\n\u003cp\u003eDiagnostic ECG units consist of a recorder unit, cables, and electrodes. The electrodes are placed on specific areas of the patient’s chest to collect electrical signals which are then sent to the recording unit via the cables.\u003c\/p\u003e\n\u003cp\u003eThese devices may use 3-, 5-, or 12-leads to record small voltages of about one millivolt (mV) that appear on the skin as a result of cardiac activity. These voltage differences directly correspond to the heart’s electrical activity and present different perspectives of the heart’s electrical activity; producing ECG waveforms in which the P waves, QRS complex, and T waves vary in amplitude and polarity.\u003c\/p\u003e\n\u003cp\u003eMultichannel ECG units record signals from two or more leads simultaneously and are frequently used in place of single-channel units. Some ECG units can perform automatic measurement and interpretation of the ECG as a selectable or optional feature.\u003c\/p\u003e\n\u003col\u003e\u003c\/ol\u003e\n\u003cstyle\u003e\u003c!--\n\u003cstrong\u003eemail address for seeking technical sales support\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003c!-- \/TABS\n--\u003e\u003c\/style\u003e","published_at":"2020-06-21T15:21:14-04:00","created_at":"2020-06-21T15:21:14-04:00","vendor":"Philips","type":"Electrocardiographs","tags":["Afghanistan","Albania","Algeria","Angola","Antigua \u0026 Barbuda","Argentina","Armenia","Austria","Azerbaijan","Bahrain","Bangladesh","Barbados","Belarus","Belize","Benin","Bhutan","Bolivia","Bosnia \u0026 Herzegovina","Botswana","Brand_Philips","Brazil","Brunei Darussalam","Bulgaria","Burkina Faso","Burundi","Cabo Verde","Cambodia","Cameroon","Category_Oxygen Therapy","Central African Republic","Chad","Chile","China","Colombia","Comoros","Congo","Costa Rica","Cote d'Ivoire","Croatia","Cyprus","Czech Republic","Democratic Republic of Congo","Dominica","Dominican Republic","Ecuador","Egypt","El Salvador","Equatorial Guinea","Eritrea","Estonia","Eswatini","Ethiopia","Federated States of Micronesia","Fiji","Gabon","Georgia","Ghana","Grenada","Guatemala","Guinea","Guinea-Bissau","Gulf Cooperation Council","Guyana","Haiti","Honduras","Hungary","India","Indonesia","Iran","Iraq","Jamaica","Jordan","Kazakhstan","Kenya","Kiribati","Korea","Kosovo","Kuwait","Kyrgyz Republic","Lao People's Democratic Republic","Latvia","Lebanon","Lesotho","Libya","Lithuania","Madagascar","Malawi","Malaysia","Maldives","Mali","Malta","Marshall Islands","Mauritania","Mauritius","Mexico","Moldova","Mongolia","Montenegro","Morocco","Mozambique","Namibia","Nepal","Nicaragua","Niger","Nigeria","North Macedonia","Oman","Pakistan","Palau","Panama","Papua New Guinea","Paraguay","Peru","Philippines","Poland","Product_Electrocardiographs","Qatar","Romania","Russian Federation","Rwanda","Samoa","Saudi Arabia","Senegal","Serbia","Seychelles","Singapore","Slovak Republic","Slovenia","Solomon Islands","Somalia","South Africa","South Sudan","Sri Lanka","St. Kitts \u0026 Nevis","St. Lucia","St. Vincent \u0026 the Grenadines","Sudan","Suriname","Syrian Arab Republic","Tajikistan","Tanzania","Thailand","The Bahamas","The Gambia","Timor-Leste","Togo","Tonga","Trinidad \u0026 Tobago","Tunisia","Turkey","Turkmenistan","Tuvalu","Uganda","Ukraine","United Arab Emirates","Uruguay","Uzbekistan","Vanuatu","Venezuela","Vietnam","West Bank \u0026 Gaza","Yemen","Zambia","Zimbabwe"],"price":156500,"price_min":156500,"price_max":174000,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":35630688993432,"title":"Not included","option1":"Not included","option2":null,"option3":null,"sku":"860392","requires_shipping":true,"taxable":false,"featured_image":null,"available":true,"name":"Philips - Electrocardiogram - PageWriter TC10 - Not included","public_title":"Not included","options":["Not included"],"price":156500,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]},{"id":35630689026200,"title":"Included","option1":"Included","option2":null,"option3":null,"sku":"860392","requires_shipping":true,"taxable":false,"featured_image":null,"available":true,"name":"Philips - Electrocardiogram - PageWriter TC10 - Included","public_title":"Included","options":["Included"],"price":174000,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0402\/1600\/2712\/products\/Electrocardiograph-Philips-PageWriterTC10.png?v=1592768301"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0402\/1600\/2712\/products\/Electrocardiograph-Philips-PageWriterTC10.png?v=1592768301","options":["Wireless"],"media":[{"alt":null,"id":9738550214808,"position":1,"preview_image":{"aspect_ratio":1.282,"height":177,"width":227,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0402\/1600\/2712\/products\/Electrocardiograph-Philips-PageWriterTC10.png?v=1592768301"},"aspect_ratio":1.282,"height":177,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0402\/1600\/2712\/products\/Electrocardiograph-Philips-PageWriterTC10.png?v=1592768301","width":227}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch4\u003eTechnical\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntended Use\u003c\/strong\u003e - Adult, pediatric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurements \u003c\/strong\u003e-\u003cstrong\u003e \u003c\/strong\u003ePhilips DXL ECG Algorithm; STEMI (ST segment elevation myocardial infarction) diagnostic aid for Culprit Artery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecorder Channels\u003c\/strong\u003e - 12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser Interface\u003c\/strong\u003e - Panel buttons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery\u003c\/strong\u003e - 2 hours continuous\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories \u0026amp; options (included)\u003c\/strong\u003e - Color touch display, welsh bulbs, 12-lead ECG algorithm, LAN option. For Wireless option: 5-Min Disclosure \u0026amp; Events, Archive \u0026amp; Inter. Query, Wireless 802.11 (a,b,g,n)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFind out more about this product\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.philips.co.uk\/healthcare\/product\/HC860392\/pagewriter-tc10-miscellaneous\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSee below for further details about the terms of this offer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eProduct Details\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch4\u003eNon Technical and Terms\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e - 36 Months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Time\u003c\/strong\u003e - Updated at time of order confirmation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping - \u003c\/strong\u003eBy Air or Sea\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService\u003c\/strong\u003e - Post-warranty service to be contracted locally by the Borrower country.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManuals\u003c\/strong\u003e - Printed user and service manuals will be provided with each piece of equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTraining\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- As part of the purchase, operator training provided at onsite for users after installing the system, if applicable. This takes place on the system purchased.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003ePricing: \u003c\/h6\u003e\n\u003cp\u003eAll prices are in USD with delivery CIP (Carriage and Insurance Paid To), place to be decided, include installation of the offered equipment and exclude VAT. Import costs, custom duties and any other additional taxes are not included.\u003c\/p\u003e\n\u003ch6\u003ePayment:\u003c\/h6\u003e\n\u003cp\u003eAdvanced payment: ten (10) percent of the Contract Price shall be paid within five (5) days of contract signing and upon submission of a claim for the amount, and thirty(30) percent of the Contract Price shall be paid within twenty (20) days of signing of the Contract and upon submission of claim and a bank demand guarantee, in the form provided in the request for invitation for direct contracting or another form acceptable to the Purchaser, for equivalent amount valid until the Goods are delivered and in the form of Advance Payment Security provided in the request for invitation for direct contracting or another form acceptable to the Purchaser.  On Shipment, sixty (60) percent of the Contract Price of the Goods shipped shall be paid, within 15 days after submission of documentation.\u003c\/p\u003e\n\u003ch6\u003eInspection\u003c\/h6\u003e\n\u003cp\u003eEquipment will be inspected by an independent agency at Philip’s warehouse (prior to shipping) to confirm quantities, shipping documentation and to ensure there is no damage to packaging. Costs related to this inspection are passed onto the Borrower Country.\u003c\/p\u003e\n\u003ch6\u003eDelivery\u003c\/h6\u003e\n\u003cp\u003ePhilips will provide delivery CIP to a designated location. Inland delivery to the hospital and local vertical transport is not included and is the Borrower country responsibility.  Under CIP the Borrower Country would be responsible for costs relating to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTerminal Charges Destination\u003c\/li\u003e\n\u003cli\u003eCustoms Clearance Import, incl. cost \u0026amp; duties\u003c\/li\u003e\n\u003cli\u003eTransport to Destination On-Carriage\u003c\/li\u003e\n\u003cli\u003eUnloading at the Borrower’s Premises\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eAbout \u0026amp; Contact\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003ePhilips Medical Systems is a global health technology company that develops and manufactures products and services for personal health, diagnosis and treatment, connected care and health informatics.\u003c\/p\u003e\n\u003ch5\u003eAbout ECG's\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003eDiagnostic electrocardiogram (ECG) units detect, record, print, and\/or display the electrical signals associated with a patient’s cardiac activity. They are used to diagnose and assist in treating some types of heart disease and arrhythmias, determine a patient’s response to drug therapy, and reveal trends or changes in heart function.\u003c\/p\u003e\n\u003cp\u003eDiagnostic ECG units consist of a recorder unit, cables, and electrodes. The electrodes are placed on specific areas of the patient’s chest to collect electrical signals which are then sent to the recording unit via the cables.\u003c\/p\u003e\n\u003cp\u003eThese devices may use 3-, 5-, or 12-leads to record small voltages of about one millivolt (mV) that appear on the skin as a result of cardiac activity. These voltage differences directly correspond to the heart’s electrical activity and present different perspectives of the heart’s electrical activity; producing ECG waveforms in which the P waves, QRS complex, and T waves vary in amplitude and polarity.\u003c\/p\u003e\n\u003cp\u003eMultichannel ECG units record signals from two or more leads simultaneously and are frequently used in place of single-channel units. Some ECG units can perform automatic measurement and interpretation of the ECG as a selectable or optional feature.\u003c\/p\u003e\n\u003col\u003e\u003c\/ol\u003e\n\u003cstyle\u003e\u003c!--\n\u003cstrong\u003eemail address for seeking technical sales support\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003c!-- \/TABS\n--\u003e\u003c\/style\u003e"}

Philips - Electrocardiogram - PageWriter TC10

Product Description

Technical

  • Intended Use - Adult, pediatric
  • Measurements - Philips DXL ECG Algorithm; STEMI (ST segment elevation myocardial infarction) diagnostic aid for Culprit Artery
  • Recorder Channels - 12
  • User Interface - Panel buttons
  • Battery - 2 hours continuous
  • Accessories & options (included) - Color touch display, welsh bulbs, 12-lead ECG algorithm, LAN option. For Wireless option: 5-Min Disclosure & Events, Archive & Inter. Query, Wireless 802.11 (a,b,g,n)

Find out more about this product here.

See below for further details about the terms of this offer.

    Log in to purchase
    Maximum quantity available reached.

    Non Technical and Terms

    • Warranty - 36 Months
    • Lead Time - Updated at time of order confirmation
    • Shipping - By Air or Sea
    • Service - Post-warranty service to be contracted locally by the Borrower country.
    • Manuals - Printed user and service manuals will be provided with each piece of equipment.
    • Training - As part of the purchase, operator training provided at onsite for users after installing the system, if applicable. This takes place on the system purchased.

    Pricing: 

    All prices are in USD with delivery CIP (Carriage and Insurance Paid To), place to be decided, include installation of the offered equipment and exclude VAT. Import costs, custom duties and any other additional taxes are not included.

    Payment:

    Advanced payment: ten (10) percent of the Contract Price shall be paid within five (5) days of contract signing and upon submission of a claim for the amount, and thirty(30) percent of the Contract Price shall be paid within twenty (20) days of signing of the Contract and upon submission of claim and a bank demand guarantee, in the form provided in the request for invitation for direct contracting or another form acceptable to the Purchaser, for equivalent amount valid until the Goods are delivered and in the form of Advance Payment Security provided in the request for invitation for direct contracting or another form acceptable to the Purchaser.  On Shipment, sixty (60) percent of the Contract Price of the Goods shipped shall be paid, within 15 days after submission of documentation.

    Inspection

    Equipment will be inspected by an independent agency at Philip’s warehouse (prior to shipping) to confirm quantities, shipping documentation and to ensure there is no damage to packaging. Costs related to this inspection are passed onto the Borrower Country.

    Delivery

    Philips will provide delivery CIP to a designated location. Inland delivery to the hospital and local vertical transport is not included and is the Borrower country responsibility.  Under CIP the Borrower Country would be responsible for costs relating to:

    • Terminal Charges Destination
    • Customs Clearance Import, incl. cost & duties
    • Transport to Destination On-Carriage
    • Unloading at the Borrower’s Premises

    Philips Medical Systems is a global health technology company that develops and manufactures products and services for personal health, diagnosis and treatment, connected care and health informatics.

    Diagnostic electrocardiogram (ECG) units detect, record, print, and/or display the electrical signals associated with a patient’s cardiac activity. They are used to diagnose and assist in treating some types of heart disease and arrhythmias, determine a patient’s response to drug therapy, and reveal trends or changes in heart function.

    Diagnostic ECG units consist of a recorder unit, cables, and electrodes. The electrodes are placed on specific areas of the patient’s chest to collect electrical signals which are then sent to the recording unit via the cables.

    These devices may use 3-, 5-, or 12-leads to record small voltages of about one millivolt (mV) that appear on the skin as a result of cardiac activity. These voltage differences directly correspond to the heart’s electrical activity and present different perspectives of the heart’s electrical activity; producing ECG waveforms in which the P waves, QRS complex, and T waves vary in amplitude and polarity.

    Multichannel ECG units record signals from two or more leads simultaneously and are frequently used in place of single-channel units. Some ECG units can perform automatic measurement and interpretation of the ECG as a selectable or optional feature.