{"id":5488350757016,"title":"Medtronic - Pulse Oximeter - Nellcor PM10N Portable","handle":"medtronic-pulse-oximeter-nellcor-pm10n-portable","description":"\u003cp\u003eThe Nellcor™ portable SpO2 patient monitoring system, PM10N\u003c\/p\u003e\n\u003ch4\u003eTechnical\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntended Use\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Spot checking and continuous monitoring \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParameters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- : Oxygen saturation (SpO2), pulse rate (PR), Percent Modulation (% Mod) output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarms\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Audio and visual, SpO2 and PR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Four (4) Li-AA\/20 hours per battery replacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories \u0026amp; Options\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Reusable Sensor Adult, Reusable Sensor Pediatric, Carry case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFind out more about this product \u003ca href=\"https:\/\/www.medtronic.com\/covidien\/en-gb\/products\/pulse-oximetry\/nellcor-portable-spo2-patient-monitoring-system.html\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSee below for further details about the terms of this offer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eProduct Details\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch4\u003eNon Technical\/Terms\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Time\u003c\/strong\u003e  - 3 - 6 weeks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- 2 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on price\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Price quoted EXW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePayment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- 40% Advance Payment \/ 60% payment on shipping. Payments to be made by Bank Direct Payment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eShipping options\u003c\/h6\u003e\n\u003col\u003e\n\u003cli\u003eCIP – if the product is supplier from abroad\u003c\/li\u003e\n\u003cli\u003eEXW – if product is supplied within the Borrower’s country\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch6\u003eShipping costs\u003c\/h6\u003e\n\u003cp\u003eOn return of the ROI, Medtronic will obtain actual shipping costs per product based on quantity and destination as per the applicable Incoterm. Actual shipping costs will be in addition to the quoted prices below and will be detailed in the contract.\u003c\/p\u003e\n\u003ch6\u003eInspection\u003c\/h6\u003e\n\u003cp\u003eMedtronic products have recognized regulatory approvals\/certificates. Medtronic will provide the Borrower with a copy of these or other documentary evidence of the approval\/certification, prior to shipment. An independent pre-shipping inspection at the place of leaving will be undertaken.  This can be arranged by Medtronic and the costs passed-through to the Borrower, or by the Borrower. \u003c\/p\u003e\n\u003ch6\u003eService\u003c\/h6\u003e\n\u003cp\u003eSupport and maintenance are most often part of the warranty on the device. \u003c\/p\u003e\n\u003ch6\u003eManuals\u003c\/h6\u003e\n\u003cp\u003ePrinted user and service manuals will be provided with each piece of equipment. In addition, all product manuals can be obtained at:\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.medtronic.com\/covidien\/en-us\/support\/product-manuals.html\" target=\"_blank\"\u003ehttps:\/\/www.medtronic.com\/covidien\/en-us\/support\/product-manuals.html\u003c\/a\u003e\u003c\/p\u003e\n\u003ch6\u003eTraining \u003c\/h6\u003e\n\u003cp\u003eClinical training is part of the Medtronic responsibility and will be provided. Medtronic has online training resources on its website. Depending on specific needs, Medtronic education team can arrange tailored videoconferences with users. Medtronic recommends that these only be arranged, after the online training has been completed.\u003c\/p\u003e\n\u003ch5\u003eAbout \u0026amp; Contact\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eMedtronic\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e (\u003ca href=\"http:\/\/www.medtronic.com\/\"\u003ewww.medtronic.com\u003c\/a\u003e) \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eis\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eone of the\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003elargest medical device companies in the world\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003ew\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eith operations in 150 countries\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eproducts\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eto\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003etreat 70 health conditions\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003ethat\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003einclude cardiac devices, cranial and spine robotics, insulin pumps, surgical tools, patient monitoring systems, and more.\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003eMedtronic’s BFP Offer relates only to devices to treat COVID-19.\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eMe\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003edt\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eroni\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003ec\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003ehas its operational headquarters in\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eMinneapolis\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e, Minnesota, USA\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003eand legal headquarters in Dublin, Eire\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e.  \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eAbout Pulse Oximeters\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003ePulse oximeters are used to noninvasively measure saturated hemoglobin in tissue capillaries. These devices are comprised of the pulse oximeter and a sensor\/probe that may designed to adhere to the patient’s finger (most common option), toe, forehead, or ear. The probe contains light emitting diodes (LEDs) that emit red and infrared lights that pass through the arteries and feeds information back to a microprocessor.\u003c\/p\u003e\n\u003cp\u003ePulse oximeters measure oxygenated and deoxygenated hemoglobin using these lights to read changing absorbance in hemoglobin due to pulsating blood flow in the arteries. This process allows for monitoring of oxygenated hemoglobin versus deoxygenated hemoglobin (not measured through light), which is revealed as an oxygenation percentage (i.e., 70% to 100%). Through this process, pulse oximeters allow for accurate monitoring of pulse rate and oxygenation percentage while providing a means of rapid detection of hypoxia, or decreased saturated oxygen rates, before onset of pathological injury and clinical symptoms.\u003c\/p\u003e\n\u003cp\u003eAdditionally, this information helps clinicians assess the amount of oxygen being carried in the blood and evaluate the need for supplemental oxygen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePulse Oximeter sensors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eECRI recommends using a higher ratio of adhesive sensors to minimize the burden and risk from cleaning and disinfecting reusable sensors between COVID-19 patient uses. \u003c\/p\u003e\n\u003cp\u003eWhen estimating\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eadhesive sensor\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003equantities, ECRI recommends planning for five adhesive sensors per week per device, which is an increase from a normal condition estimates of four sensors per week.\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAdhesive sensors are intended for single patient use only.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003ereusable sensors,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eECRI recommends purchasing 12 sensors per device. \u003c\/p\u003e\n\u003col\u003e\u003c\/ol\u003e","published_at":"2020-07-15T08:13:20-04:00","created_at":"2020-07-15T08:13:17-04:00","vendor":"Medtronic","type":"Pulse Oximeters","tags":["Afghanistan","Albania","Algeria","Angola","Antigua and Barbuda","Arab Republic of","Argentina","Armenia","Azerbaijan","Bahamas","Bahrain","Bangladesh","Barbados","Belarus","Belize","Benin","Bhutan","Bolivia","Bosnia and Herzegovina","Botswana","Brand_Medtronic","Brazil","Brunei Darussalam","Bulgaria","Burkina Faso","Burundi","Cabo Verde","Cambodia","Cameroon","Central African Republic","Chad","Chile","China","Colombia","Comoros","Congo","Costa Rica","Cote D'ivoire","Croatia","Cyprus","Czech Republic","Democratic Republic of","Djibouti","Dominica","Dominican Republic","Ecuador","Egypt","El Salvador","Equatorial Guinea","Eritrea","Estonia","Eswatini","Ethiopia","Federated States of","Fiji","Gabon","Gambia","Georgia","Ghana","Grenada","Guatemala","Guinea","Guinea-Bissau","Gulf Cooperation Council","Guyana","Haiti","Honduras","Hungary","India","Indonesia","Iran","Iraq","Islamic Republic of","Jamaica","Jordan","Kazakhstan","Kenya","Kiribati","Korea","Kosovo","Kuwait","Kyrgyz Republic","Lao People's Democratic Republic","Latvia","Lebanon","Lesotho","Liberia","Libya","Lithuania","Madagascar","Malawi","Malaysia","Maldives","Mali","Malta","Marshall Islands","Mauritania","Mauritius","Mexico","Micronesia","Moldova","Mongolia","Montenegro","Morocco","Mozambique","Myanmar","Namibia","Nepal","Nicaragua","Niger","Nigeria","North Macedonia","Oman","Order_Zambia","Pakistan","Palau","Panama","Papua New Guinea","Paraguay","Peru","Philippines","Poland","Product_Pulse Oximeters","Qatar","Republic of","Republica Bolivariana de","Romania","Russian Federation","Rwanda","Samoa","Sao Tome and Principe","Saudi Arabia","Senegal","Serbia","Seychelles","Sierra Leone","Singapore","Slovak Republic","Slovenia","Solomon Islands","Somalia","South Africa","South Sudan","Sri Lanka","St. Kitts and Nevis","St. Lucia","St. Vincent and the Grenadines","Sudan","Suriname","Syrian Arab Republic","Tajikistan","Tanzania","Thailand","Timor-Leste","Togo","Tonga","Trinidad and Tobago","Tunisia","Turkey","Turkmenistan","Tuvalu","Uganda","Ukraine","Uruguay","Uzbekistan","Vanuatu","Venezuela","Vietnam","West Bank And Gaza","Yemen","Zambia","Zimbabwe"],"price":40000,"price_min":40000,"price_max":40000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":35270741164184,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":false,"featured_image":null,"available":true,"name":"Medtronic - Pulse Oximeter - Nellcor PM10N Portable","public_title":null,"options":["Default Title"],"price":40000,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0402\/1600\/2712\/products\/Photo4_cv_PM10N_Beauty4_0114.jpg?v=1597844690"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0402\/1600\/2712\/products\/Photo4_cv_PM10N_Beauty4_0114.jpg?v=1597844690","options":["Title"],"media":[{"alt":null,"id":11025783062680,"position":1,"preview_image":{"aspect_ratio":0.695,"height":800,"width":556,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0402\/1600\/2712\/products\/Photo4_cv_PM10N_Beauty4_0114.jpg?v=1597844690"},"aspect_ratio":0.695,"height":800,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0402\/1600\/2712\/products\/Photo4_cv_PM10N_Beauty4_0114.jpg?v=1597844690","width":556}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe Nellcor™ portable SpO2 patient monitoring system, PM10N\u003c\/p\u003e\n\u003ch4\u003eTechnical\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntended Use\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Spot checking and continuous monitoring \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParameters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- : Oxygen saturation (SpO2), pulse rate (PR), Percent Modulation (% Mod) output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarms\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Audio and visual, SpO2 and PR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Four (4) Li-AA\/20 hours per battery replacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories \u0026amp; Options\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Reusable Sensor Adult, Reusable Sensor Pediatric, Carry case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFind out more about this product \u003ca href=\"https:\/\/www.medtronic.com\/covidien\/en-gb\/products\/pulse-oximetry\/nellcor-portable-spo2-patient-monitoring-system.html\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSee below for further details about the terms of this offer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eProduct Details\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch4\u003eNon Technical\/Terms\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Time\u003c\/strong\u003e  - 3 - 6 weeks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- 2 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on price\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Price quoted EXW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePayment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- 40% Advance Payment \/ 60% payment on shipping. Payments to be made by Bank Direct Payment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eShipping options\u003c\/h6\u003e\n\u003col\u003e\n\u003cli\u003eCIP – if the product is supplier from abroad\u003c\/li\u003e\n\u003cli\u003eEXW – if product is supplied within the Borrower’s country\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch6\u003eShipping costs\u003c\/h6\u003e\n\u003cp\u003eOn return of the ROI, Medtronic will obtain actual shipping costs per product based on quantity and destination as per the applicable Incoterm. Actual shipping costs will be in addition to the quoted prices below and will be detailed in the contract.\u003c\/p\u003e\n\u003ch6\u003eInspection\u003c\/h6\u003e\n\u003cp\u003eMedtronic products have recognized regulatory approvals\/certificates. Medtronic will provide the Borrower with a copy of these or other documentary evidence of the approval\/certification, prior to shipment. An independent pre-shipping inspection at the place of leaving will be undertaken.  This can be arranged by Medtronic and the costs passed-through to the Borrower, or by the Borrower. \u003c\/p\u003e\n\u003ch6\u003eService\u003c\/h6\u003e\n\u003cp\u003eSupport and maintenance are most often part of the warranty on the device. \u003c\/p\u003e\n\u003ch6\u003eManuals\u003c\/h6\u003e\n\u003cp\u003ePrinted user and service manuals will be provided with each piece of equipment. In addition, all product manuals can be obtained at:\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.medtronic.com\/covidien\/en-us\/support\/product-manuals.html\" target=\"_blank\"\u003ehttps:\/\/www.medtronic.com\/covidien\/en-us\/support\/product-manuals.html\u003c\/a\u003e\u003c\/p\u003e\n\u003ch6\u003eTraining \u003c\/h6\u003e\n\u003cp\u003eClinical training is part of the Medtronic responsibility and will be provided. Medtronic has online training resources on its website. Depending on specific needs, Medtronic education team can arrange tailored videoconferences with users. Medtronic recommends that these only be arranged, after the online training has been completed.\u003c\/p\u003e\n\u003ch5\u003eAbout \u0026amp; Contact\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eMedtronic\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e (\u003ca href=\"http:\/\/www.medtronic.com\/\"\u003ewww.medtronic.com\u003c\/a\u003e) \u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eis\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eone of the\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003elargest medical device companies in the world\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003ew\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eith operations in 150 countries\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eproducts\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eto\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003etreat 70 health conditions\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003ethat\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003einclude cardiac devices, cranial and spine robotics, insulin pumps, surgical tools, patient monitoring systems, and more.\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003eMedtronic’s BFP Offer relates only to devices to treat COVID-19.\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eMe\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003edt\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eroni\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003ec\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003ehas its operational headquarters in\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eMinneapolis\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e, Minnesota, USA\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003eand legal headquarters in Dublin, Eire\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-contrast=\"none\" class=\"TextRun SCXW241321036 BCX0\" lang=\"EN-NZ\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e.  \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eAbout Pulse Oximeters\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003ePulse oximeters are used to noninvasively measure saturated hemoglobin in tissue capillaries. These devices are comprised of the pulse oximeter and a sensor\/probe that may designed to adhere to the patient’s finger (most common option), toe, forehead, or ear. The probe contains light emitting diodes (LEDs) that emit red and infrared lights that pass through the arteries and feeds information back to a microprocessor.\u003c\/p\u003e\n\u003cp\u003ePulse oximeters measure oxygenated and deoxygenated hemoglobin using these lights to read changing absorbance in hemoglobin due to pulsating blood flow in the arteries. This process allows for monitoring of oxygenated hemoglobin versus deoxygenated hemoglobin (not measured through light), which is revealed as an oxygenation percentage (i.e., 70% to 100%). Through this process, pulse oximeters allow for accurate monitoring of pulse rate and oxygenation percentage while providing a means of rapid detection of hypoxia, or decreased saturated oxygen rates, before onset of pathological injury and clinical symptoms.\u003c\/p\u003e\n\u003cp\u003eAdditionally, this information helps clinicians assess the amount of oxygen being carried in the blood and evaluate the need for supplemental oxygen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePulse Oximeter sensors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eECRI recommends using a higher ratio of adhesive sensors to minimize the burden and risk from cleaning and disinfecting reusable sensors between COVID-19 patient uses. \u003c\/p\u003e\n\u003cp\u003eWhen estimating\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eadhesive sensor\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003equantities, ECRI recommends planning for five adhesive sensors per week per device, which is an increase from a normal condition estimates of four sensors per week.\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAdhesive sensors are intended for single patient use only.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003ereusable sensors,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eECRI recommends purchasing 12 sensors per device. \u003c\/p\u003e\n\u003col\u003e\u003c\/ol\u003e"}

Medtronic - Pulse Oximeter - Nellcor PM10N Portable

Product Description

The Nellcor™ portable SpO2 patient monitoring system, PM10N

Technical

  • Intended Use - Spot checking and continuous monitoring 
  • Parameters - : Oxygen saturation (SpO2), pulse rate (PR), Percent Modulation (% Mod) output
  • Alarms - Audio and visual, SpO2 and PR
  • Battery - Four (4) Li-AA/20 hours per battery replacement
  • Accessories & Options - Reusable Sensor Adult, Reusable Sensor Pediatric, Carry case

Find out more about this product here

See below for further details about the terms of this offer.

Log in to purchase
Maximum quantity available reached.

Non Technical/Terms

  • Lead Time  - 3 - 6 weeks
  • Warranty - 2 years
  • Note on price - Price quoted EXW
  • Payment - 40% Advance Payment / 60% payment on shipping. Payments to be made by Bank Direct Payment.
Shipping options
  1. CIP – if the product is supplier from abroad
  2. EXW – if product is supplied within the Borrower’s country
Shipping costs

On return of the ROI, Medtronic will obtain actual shipping costs per product based on quantity and destination as per the applicable Incoterm. Actual shipping costs will be in addition to the quoted prices below and will be detailed in the contract.

Inspection

Medtronic products have recognized regulatory approvals/certificates. Medtronic will provide the Borrower with a copy of these or other documentary evidence of the approval/certification, prior to shipment. An independent pre-shipping inspection at the place of leaving will be undertaken.  This can be arranged by Medtronic and the costs passed-through to the Borrower, or by the Borrower. 

Service

Support and maintenance are most often part of the warranty on the device. 

Manuals

Printed user and service manuals will be provided with each piece of equipment. In addition, all product manuals can be obtained at: https://www.medtronic.com/covidien/en-us/support/product-manuals.html

Training 

Clinical training is part of the Medtronic responsibility and will be provided. Medtronic has online training resources on its website. Depending on specific needs, Medtronic education team can arrange tailored videoconferences with users. Medtronic recommends that these only be arranged, after the online training has been completed.

Medtronic (www.medtronic.comis one of the largest medical device companies in the world with operations in 150 countries, and products to treat 70 health conditions that include cardiac devices, cranial and spine robotics, insulin pumps, surgical tools, patient monitoring systems, and more. Medtronic’s BFP Offer relates only to devices to treat COVID-19. Medtronic has its operational headquarters in Minneapolis, Minnesota, USA and legal headquarters in Dublin, Eire.  

Pulse oximeters are used to noninvasively measure saturated hemoglobin in tissue capillaries. These devices are comprised of the pulse oximeter and a sensor/probe that may designed to adhere to the patient’s finger (most common option), toe, forehead, or ear. The probe contains light emitting diodes (LEDs) that emit red and infrared lights that pass through the arteries and feeds information back to a microprocessor.

Pulse oximeters measure oxygenated and deoxygenated hemoglobin using these lights to read changing absorbance in hemoglobin due to pulsating blood flow in the arteries. This process allows for monitoring of oxygenated hemoglobin versus deoxygenated hemoglobin (not measured through light), which is revealed as an oxygenation percentage (i.e., 70% to 100%). Through this process, pulse oximeters allow for accurate monitoring of pulse rate and oxygenation percentage while providing a means of rapid detection of hypoxia, or decreased saturated oxygen rates, before onset of pathological injury and clinical symptoms.

Additionally, this information helps clinicians assess the amount of oxygen being carried in the blood and evaluate the need for supplemental oxygen.

Pulse Oximeter sensors

ECRI recommends using a higher ratio of adhesive sensors to minimize the burden and risk from cleaning and disinfecting reusable sensors between COVID-19 patient uses. 

When estimating adhesive sensor quantities, ECRI recommends planning for five adhesive sensors per week per device, which is an increase from a normal condition estimates of four sensors per week. Adhesive sensors are intended for single patient use only.

For reusable sensors, ECRI recommends purchasing 12 sensors per device.