{"id":5318490063000,"title":"Medtronic - Ventilator - PB980 Intensive Care","handle":"medtronic-pb980-ventilator","description":"\u003ch4\u003eTechnical\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntended Use\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Adult, Pediatric, Neonates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- A\/C VC, A\/C PC, SIMV, SPONT, BiLevel, CPAP, VC, PC, VC+, PS, VS, TC, PAV+, NIV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTidal Volume\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- 2 to 2500mL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Inspiratory Flow \u003c\/strong\u003e-\u003cstrong\u003e 200\u003c\/strong\u003e L\/min\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPAP\/PEEP Support\u003c\/strong\u003e - 0.0 to 45 cm H2O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Pressure Support\u003c\/strong\u003e - 90 cm H2O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarms\u003c\/strong\u003e - Full capabilities\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery - \u003c\/strong\u003eRechargeable in 60 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories \u0026amp; Options\u003c\/strong\u003e - DAR Double limb circuit, box of 10 (SKU# 301\/6378) \/ 980 PAED \/ ADT Expiratory filter, box of 12 (SKU# 10043551) \/ Inspiratory Bacteria filter, box of 12 (SKU# 351U5856)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFind out more about this product \u003ca href=\"https:\/\/www.medtronic.com\/covidien\/en-us\/products\/mechanical-ventilation\/puritan-bennett-980-ventilator.html\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSee below for further details about the terms of this offer.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eProduct Details\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch4\u003eNon Technical\/Terms\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Time\u003c\/strong\u003e  - 7 months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- 2 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on price\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Price quoted EXW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePayment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- 40% Advance Payment \/ 60% payment on shipping. Payments to be made by Bank Direct Payment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eShipping options\u003c\/h6\u003e\n\u003col\u003e\n\u003cli\u003eCIP – if the product is supplier from abroad\u003c\/li\u003e\n\u003cli\u003eEXW – if product is supplied within the Borrower’s country\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch6\u003eShipping costs\u003c\/h6\u003e\n\u003cp\u003eOn return of the ROI, Medtronic will obtain actual shipping costs per product based on quantity and destination as per the applicable Incoterm. Actual shipping costs will be in addition to the quoted prices below and will be detailed in the contract.\u003c\/p\u003e\n\u003ch6\u003eInspection\u003c\/h6\u003e\n\u003cp\u003eMedtronic products have recognized regulatory approvals\/certificates. Medtronic will provide the Borrower with a copy of these or other documentary evidence of the approval\/certification, prior to shipment. An independent pre-shipping inspection at the place of leaving will be undertaken.  This can be arranged by Medtronic and the costs passed-through to the Borrower, or by the Borrower. \u003c\/p\u003e\n\u003ch6\u003eService\u003c\/h6\u003e\n\u003cp\u003eSupport and maintenance are most often part of the warranty on the device. \u003c\/p\u003e\n\u003ch6\u003eManuals\u003c\/h6\u003e\n\u003cp\u003ePrinted user and service manuals will be provided with each piece of equipment. In addition, all product manuals can be obtained at:\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.medtronic.com\/covidien\/en-us\/support\/product-manuals.html\" target=\"_blank\"\u003ehttps:\/\/www.medtronic.com\/covidien\/en-us\/support\/product-manuals.html\u003c\/a\u003e\u003c\/p\u003e\n\u003ch6\u003eTraining \u003c\/h6\u003e\n\u003cp\u003eClinical training is part of the Medtronic responsibility and will be provided. Medtronic has online training resources on its website. Depending on specific needs, Medtronic education team can arrange tailored videoconferences with users. Medtronic recommends that these only be arranged, after the online training has been completed.\u003c\/p\u003e\n\u003ch5\u003eAbout \u0026amp; Contact\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eMedtronic\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e (\u003ca href=\"http:\/\/www.medtronic.com\/\"\u003ewww.medtronic.com\u003c\/a\u003e) \u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eis\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eone of the\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003elargest medical device companies in the world\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003ew\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eith operations in 150 countries\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eproducts\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eto\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003etreat 70 health conditions\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003ethat\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003einclude cardiac devices, cranial and spine robotics, insulin pumps, surgical tools, patient monitoring systems, and more.\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003eMedtronic’s BFP Offer relates only to devices to treat COVID-19.\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eMe\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003edt\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eroni\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003ec\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003ehas its operational headquarters in\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eMinneapolis\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e, Minnesota, USA\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003eand legal headquarters in Dublin, Eire\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e.  \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eAbout Ventilators\u003c\/h5\u003e\n\u003ch6\u003eVentilators\u003c\/h6\u003e\n\u003cp\u003eVentilators are pieces of medical equipment that provide ventilatory support to patients who cannot maintain adequate ventilation or oxygenation on their own due to illness, trauma, congenital defects or drugs. \u003c\/p\u003e\n\u003cp\u003eVentilators typically consist of a flexible breathing circuit, a pneumatic system, a control system, monitors and alarms. Depending on the type and complexity of the ventilator, the gas is delivered either using a single or dual limb breathing circuit. Most ventilators are microprocessor controlled to control the pressure, volume, and Fi02. Power is supplied from either an electrical wall outlet and\/or a battery.\u003c\/p\u003e\n\u003cp\u003eAll ventilators require a source of oxygen. Critical care ventilators always require a source of oxygen at high pressure (approximately 4 Bar) while other ventilators require a high pressure or low flow (2-15 l\/m) source of oxygen, depending on the individual ventilator. Mechanical ventilators have several operating modes which are chosen by clinicians to define breath initiation and end (i.e., cycle) as well as adjustable parameters such as pressure and flow. Different modes can also provide either full or partial ventilatory support, depending on the individual patient’s condition and clinical requirements.\u003c\/p\u003e\n\u003ch6\u003eHigh Flow Delivery Devices\u003c\/h6\u003e\n\u003cp\u003eHigh-flow oxygen delivery systems, commonly referred to as a High Flow Nasal Cannula (HFNC) supply a given oxygen concentration at a higher than normal flow rate to the patient. These systems generally consist of three parts: the flow generator, an air-oxygen blender, and a heated humidifier. The heated and humidified air-oxygen is delivered to the patient via a specially designed nasal cannula.\u003c\/p\u003e\n\u003cp\u003eThe benefits of high-flow oxygen include the improvement of gas exchange and the decrease in the work of breathing. High-flow devices are capable of delivering a maximum flow of 60 l\/min and all require a high-pressure source of air and oxygen at approximately 4 bars.\u003c\/p\u003e\n\u003col\u003e\u003c\/ol\u003e\n\u003cstyle\u003e\u003c!--\n\u003cstrong\u003eemail address for seeking technical sales support\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003c!-- \/TABS\n--\u003e\u003c\/style\u003e","published_at":"2020-06-09T01:43:52-04:00","created_at":"2020-06-09T01:26:14-04:00","vendor":"Medtronic","type":"Ventilators","tags":["Algeria","Angola","Benin","Botswana","Brand_Medtronic","Burkina Faso","Burundi","Cameroon","Cape Verde","Category_Critical Care Ventilator","Category_Oxygen Therapy","Central African Republic","Chad","Comoros","Congo","Cote d'Ivoire","Djibouti","Egypt","Equatorial Guinea","Ethiopia","Gabon","Gambia","Ghana","Guinea","Guinea-Bissau","Guyana","Kenya","Lesotho","Liberia","Libya","Madagascar","Malawi","Mali","Mauritania","Mauritius","Morocco","Mozambique","Namibia","Niger","Nigeria","Order_Guyana","Product_Ventilators","Republic of","Republic of Sierra Leone","Rwanda","Sao Tome and Principe","Senegal","Seychelles","Somalia","South Africa","Sudan","Swaziland","Tanzania","Togo","Tunisia","Uganda","Zambia","Zimbabwe"],"price":3000000,"price_min":3000000,"price_max":3500000,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":35854093156504,"title":"Pediatric \/ Adult Configuration Standard \/ No","option1":"Pediatric \/ Adult Configuration Standard","option2":"No","option3":null,"sku":"","requires_shipping":true,"taxable":false,"featured_image":null,"available":true,"name":"Medtronic - Ventilator - PB980 Intensive Care - Pediatric \/ Adult Configuration Standard \/ No","public_title":"Pediatric \/ Adult Configuration Standard \/ No","options":["Pediatric \/ Adult Configuration Standard","No"],"price":3000000,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":35854093189272,"title":"Universal Configuration Standard \/ No","option1":"Universal Configuration Standard","option2":"No","option3":null,"sku":"","requires_shipping":true,"taxable":false,"featured_image":null,"available":true,"name":"Medtronic - Ventilator - PB980 Intensive Care - Universal Configuration Standard \/ No","public_title":"Universal Configuration Standard \/ No","options":["Universal Configuration Standard","No"],"price":3200000,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":35854129856664,"title":"Pediatric \/ Adult Configuration Standard \/ Yes","option1":"Pediatric \/ Adult Configuration Standard","option2":"Yes","option3":null,"sku":"","requires_shipping":true,"taxable":false,"featured_image":null,"available":true,"name":"Medtronic - Ventilator - PB980 Intensive Care - Pediatric \/ Adult Configuration Standard \/ Yes","public_title":"Pediatric \/ Adult Configuration Standard \/ Yes","options":["Pediatric \/ Adult Configuration Standard","Yes"],"price":3300000,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":35854134444184,"title":"Universal Configuration Standard \/ Yes","option1":"Universal Configuration Standard","option2":"Yes","option3":null,"sku":"","requires_shipping":true,"taxable":false,"featured_image":null,"available":true,"name":"Medtronic - Ventilator - PB980 Intensive Care - Universal Configuration Standard \/ Yes","public_title":"Universal Configuration Standard \/ Yes","options":["Universal Configuration Standard","Yes"],"price":3500000,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0402\/1600\/2712\/products\/MedtronicPB980.png?v=1594698406"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0402\/1600\/2712\/products\/MedtronicPB980.png?v=1594698406","options":["Configuration","Compressor Included"],"media":[{"alt":null,"id":10172347121816,"position":1,"preview_image":{"aspect_ratio":0.448,"height":362,"width":162,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0402\/1600\/2712\/products\/MedtronicPB980.png?v=1594698406"},"aspect_ratio":0.448,"height":362,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0402\/1600\/2712\/products\/MedtronicPB980.png?v=1594698406","width":162}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch4\u003eTechnical\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntended Use\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Adult, Pediatric, Neonates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- A\/C VC, A\/C PC, SIMV, SPONT, BiLevel, CPAP, VC, PC, VC+, PS, VS, TC, PAV+, NIV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTidal Volume\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- 2 to 2500mL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Inspiratory Flow \u003c\/strong\u003e-\u003cstrong\u003e 200\u003c\/strong\u003e L\/min\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPAP\/PEEP Support\u003c\/strong\u003e - 0.0 to 45 cm H2O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Pressure Support\u003c\/strong\u003e - 90 cm H2O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarms\u003c\/strong\u003e - Full capabilities\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery - \u003c\/strong\u003eRechargeable in 60 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories \u0026amp; Options\u003c\/strong\u003e - DAR Double limb circuit, box of 10 (SKU# 301\/6378) \/ 980 PAED \/ ADT Expiratory filter, box of 12 (SKU# 10043551) \/ Inspiratory Bacteria filter, box of 12 (SKU# 351U5856)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFind out more about this product \u003ca href=\"https:\/\/www.medtronic.com\/covidien\/en-us\/products\/mechanical-ventilation\/puritan-bennett-980-ventilator.html\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSee below for further details about the terms of this offer.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- TABS --\u003e\n\u003ch5\u003eProduct Details\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch4\u003eNon Technical\/Terms\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Time\u003c\/strong\u003e  - 7 months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- 2 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote on price\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Price quoted EXW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePayment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- 40% Advance Payment \/ 60% payment on shipping. Payments to be made by Bank Direct Payment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eShipping options\u003c\/h6\u003e\n\u003col\u003e\n\u003cli\u003eCIP – if the product is supplier from abroad\u003c\/li\u003e\n\u003cli\u003eEXW – if product is supplied within the Borrower’s country\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch6\u003eShipping costs\u003c\/h6\u003e\n\u003cp\u003eOn return of the ROI, Medtronic will obtain actual shipping costs per product based on quantity and destination as per the applicable Incoterm. Actual shipping costs will be in addition to the quoted prices below and will be detailed in the contract.\u003c\/p\u003e\n\u003ch6\u003eInspection\u003c\/h6\u003e\n\u003cp\u003eMedtronic products have recognized regulatory approvals\/certificates. Medtronic will provide the Borrower with a copy of these or other documentary evidence of the approval\/certification, prior to shipment. An independent pre-shipping inspection at the place of leaving will be undertaken.  This can be arranged by Medtronic and the costs passed-through to the Borrower, or by the Borrower. \u003c\/p\u003e\n\u003ch6\u003eService\u003c\/h6\u003e\n\u003cp\u003eSupport and maintenance are most often part of the warranty on the device. \u003c\/p\u003e\n\u003ch6\u003eManuals\u003c\/h6\u003e\n\u003cp\u003ePrinted user and service manuals will be provided with each piece of equipment. In addition, all product manuals can be obtained at:\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.medtronic.com\/covidien\/en-us\/support\/product-manuals.html\" target=\"_blank\"\u003ehttps:\/\/www.medtronic.com\/covidien\/en-us\/support\/product-manuals.html\u003c\/a\u003e\u003c\/p\u003e\n\u003ch6\u003eTraining \u003c\/h6\u003e\n\u003cp\u003eClinical training is part of the Medtronic responsibility and will be provided. Medtronic has online training resources on its website. Depending on specific needs, Medtronic education team can arrange tailored videoconferences with users. Medtronic recommends that these only be arranged, after the online training has been completed.\u003c\/p\u003e\n\u003ch5\u003eAbout \u0026amp; Contact\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eMedtronic\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e (\u003ca href=\"http:\/\/www.medtronic.com\/\"\u003ewww.medtronic.com\u003c\/a\u003e) \u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eis\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eone of the\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003elargest medical device companies in the world\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003ew\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eith operations in 150 countries\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eproducts\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eto\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003etreat 70 health conditions\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003ethat\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003einclude cardiac devices, cranial and spine robotics, insulin pumps, surgical tools, patient monitoring systems, and more.\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003eMedtronic’s BFP Offer relates only to devices to treat COVID-19.\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eMe\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003edt\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eroni\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003ec\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003ehas its operational headquarters in\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003eMinneapolis\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e, Minnesota, USA\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e\u003cspan\u003e \u003c\/span\u003eand legal headquarters in Dublin, Eire\u003c\/span\u003e\u003c\/span\u003e\u003cspan lang=\"EN-NZ\" class=\"TextRun SCXW241321036 BCX0\" data-contrast=\"none\" xml:lang=\"EN-NZ\"\u003e\u003cspan class=\"NormalTextRun SCXW241321036 BCX0\"\u003e.  \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eAbout Ventilators\u003c\/h5\u003e\n\u003ch6\u003eVentilators\u003c\/h6\u003e\n\u003cp\u003eVentilators are pieces of medical equipment that provide ventilatory support to patients who cannot maintain adequate ventilation or oxygenation on their own due to illness, trauma, congenital defects or drugs. \u003c\/p\u003e\n\u003cp\u003eVentilators typically consist of a flexible breathing circuit, a pneumatic system, a control system, monitors and alarms. Depending on the type and complexity of the ventilator, the gas is delivered either using a single or dual limb breathing circuit. Most ventilators are microprocessor controlled to control the pressure, volume, and Fi02. Power is supplied from either an electrical wall outlet and\/or a battery.\u003c\/p\u003e\n\u003cp\u003eAll ventilators require a source of oxygen. Critical care ventilators always require a source of oxygen at high pressure (approximately 4 Bar) while other ventilators require a high pressure or low flow (2-15 l\/m) source of oxygen, depending on the individual ventilator. Mechanical ventilators have several operating modes which are chosen by clinicians to define breath initiation and end (i.e., cycle) as well as adjustable parameters such as pressure and flow. Different modes can also provide either full or partial ventilatory support, depending on the individual patient’s condition and clinical requirements.\u003c\/p\u003e\n\u003ch6\u003eHigh Flow Delivery Devices\u003c\/h6\u003e\n\u003cp\u003eHigh-flow oxygen delivery systems, commonly referred to as a High Flow Nasal Cannula (HFNC) supply a given oxygen concentration at a higher than normal flow rate to the patient. These systems generally consist of three parts: the flow generator, an air-oxygen blender, and a heated humidifier. The heated and humidified air-oxygen is delivered to the patient via a specially designed nasal cannula.\u003c\/p\u003e\n\u003cp\u003eThe benefits of high-flow oxygen include the improvement of gas exchange and the decrease in the work of breathing. High-flow devices are capable of delivering a maximum flow of 60 l\/min and all require a high-pressure source of air and oxygen at approximately 4 bars.\u003c\/p\u003e\n\u003col\u003e\u003c\/ol\u003e\n\u003cstyle\u003e\u003c!--\n\u003cstrong\u003eemail address for seeking technical sales support\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003c!-- \/TABS\n--\u003e\u003c\/style\u003e"}

Medtronic - Ventilator - PB980 Intensive Care

Product Description

Technical

  • Intended Use - Adult, Pediatric, Neonates
  • Modes - A/C VC, A/C PC, SIMV, SPONT, BiLevel, CPAP, VC, PC, VC+, PS, VS, TC, PAV+, NIV
  • Tidal Volume - 2 to 2500mL
  • Peak Inspiratory Flow - 200 L/min
  • CPAP/PEEP Support - 0.0 to 45 cm H2O
  • Max Pressure Support - 90 cm H2O
  • Alarms - Full capabilities
  • Battery - Rechargeable in 60 minutes
  • Accessories & Options - DAR Double limb circuit, box of 10 (SKU# 301/6378) / 980 PAED / ADT Expiratory filter, box of 12 (SKU# 10043551) / Inspiratory Bacteria filter, box of 12 (SKU# 351U5856)

Find out more about this product here

See below for further details about the terms of this offer.

Log in to purchase
Maximum quantity available reached.

Non Technical/Terms

  • Lead Time  - 7 months
  • Warranty - 2 years
  • Note on price - Price quoted EXW
  • Payment - 40% Advance Payment / 60% payment on shipping. Payments to be made by Bank Direct Payment.
Shipping options
  1. CIP – if the product is supplier from abroad
  2. EXW – if product is supplied within the Borrower’s country
Shipping costs

On return of the ROI, Medtronic will obtain actual shipping costs per product based on quantity and destination as per the applicable Incoterm. Actual shipping costs will be in addition to the quoted prices below and will be detailed in the contract.

Inspection

Medtronic products have recognized regulatory approvals/certificates. Medtronic will provide the Borrower with a copy of these or other documentary evidence of the approval/certification, prior to shipment. An independent pre-shipping inspection at the place of leaving will be undertaken.  This can be arranged by Medtronic and the costs passed-through to the Borrower, or by the Borrower. 

Service

Support and maintenance are most often part of the warranty on the device. 

Manuals

Printed user and service manuals will be provided with each piece of equipment. In addition, all product manuals can be obtained at: https://www.medtronic.com/covidien/en-us/support/product-manuals.html

Training 

Clinical training is part of the Medtronic responsibility and will be provided. Medtronic has online training resources on its website. Depending on specific needs, Medtronic education team can arrange tailored videoconferences with users. Medtronic recommends that these only be arranged, after the online training has been completed.

Medtronic (www.medtronic.comis one of the largest medical device companies in the world with operations in 150 countries, and products to treat 70 health conditions that include cardiac devices, cranial and spine robotics, insulin pumps, surgical tools, patient monitoring systems, and more. Medtronic’s BFP Offer relates only to devices to treat COVID-19. Medtronic has its operational headquarters in Minneapolis, Minnesota, USA and legal headquarters in Dublin, Eire.  

Ventilators

Ventilators are pieces of medical equipment that provide ventilatory support to patients who cannot maintain adequate ventilation or oxygenation on their own due to illness, trauma, congenital defects or drugs. 

Ventilators typically consist of a flexible breathing circuit, a pneumatic system, a control system, monitors and alarms. Depending on the type and complexity of the ventilator, the gas is delivered either using a single or dual limb breathing circuit. Most ventilators are microprocessor controlled to control the pressure, volume, and Fi02. Power is supplied from either an electrical wall outlet and/or a battery.

All ventilators require a source of oxygen. Critical care ventilators always require a source of oxygen at high pressure (approximately 4 Bar) while other ventilators require a high pressure or low flow (2-15 l/m) source of oxygen, depending on the individual ventilator. Mechanical ventilators have several operating modes which are chosen by clinicians to define breath initiation and end (i.e., cycle) as well as adjustable parameters such as pressure and flow. Different modes can also provide either full or partial ventilatory support, depending on the individual patient’s condition and clinical requirements.

High Flow Delivery Devices

High-flow oxygen delivery systems, commonly referred to as a High Flow Nasal Cannula (HFNC) supply a given oxygen concentration at a higher than normal flow rate to the patient. These systems generally consist of three parts: the flow generator, an air-oxygen blender, and a heated humidifier. The heated and humidified air-oxygen is delivered to the patient via a specially designed nasal cannula.

The benefits of high-flow oxygen include the improvement of gas exchange and the decrease in the work of breathing. High-flow devices are capable of delivering a maximum flow of 60 l/min and all require a high-pressure source of air and oxygen at approximately 4 bars.